Product Description
STATF-1700X high temperature vacuum gas tube furnace is a precision vacuum tubular furnace using quality ceramic STA Super 1800 MoSi2 heating elements as heating elements. It is widely used for materials or chemical lab to sinter all types of new materials samples under vacuum or other gases condition. It is controlled by high precision SCR ( Silicon Controlled Rectifier) digital controller with accuracy +/-1.C and 30 segments programmable up to 1700.C.
Now our vacuum tube furnaces is widely used in university labs for CVD study.
CE Certified 1700C High Temperature Vacuum Tubes Furnace STATF-1800X (Dia 10-120mm) Support Customized size
Model: STATF-1700X | |
Main Specifications: | |
Inside Chamber Size | Dia60x300mm(dia2.5" x 12") (support customized size) |
Standard Working Temperature | <1700 C ( continuous ) |
Maximum Working Temperature | 1700 C ( < 3 hrs) |
Furnace chamber | split type |
Max. vacuum | -0.1MPa |
Temperature Control | 30 steps programmable and PID automatic control |
Heating Rate | 0~ 40.C/ min (suggestion: =< 20.C ) |
Temperature Accuracy | +/- 1 .C |
Furnace structure | Double shell with fan cooling |
Heating Element | STA SUPER 1800 heating elements |
Thermocouple | B type |
Working Voltage | AC 208-240V Single/Three Phase 60/50 Hz (or according to your requirement) |
Max. Power | 8.5 KW |
Net Weight | 180kg |
Detailed Description | |
STATF-1700X tube furnace is a precision bench-top furnace using quality ceramic MoSi2 rods as heating elements. It is widely used for materials or chemical lab to sinter all types of new materials samples under vacuum or other gases condition. It is controlled by high precision SCR ( Silicon Controlled Rectifier) digital controller with accuracy +/-1.C and 30 segments programmable up to 1700.C | |
Standard package included with the furnaces | |
Part description | Quantity |
Tube plug | 4pcs |
quartz tube | 1pc |
vacuum pump | 1pc |
Sealing flange | 1set |
vacuum gauge | 1pc |
Thermal couple | 1 pc |
Stainless steel hook | 1 pc |
Thermal gloves | 1 pair |
Operation manual | 1 pc |
Standard size of STA CVD tube furnace:
Model | Chamber size (OD x heating length) | Max. Temperature |
STATF-1700X | Dia40x300mm (1.5"x12") | 1700 C |
STATF-1700X | Dia40x450mm (1.5"x18") | 1700 C |
STATF-1700X | Dia60x300mm (2.5"x12") | 1700 C |
STATF-1700X | Dia60x450mm (2.5"x18") | 1700 C |
STATF-1700X | Dia80x300mm (3.0"x12") | 1700 C |
STATF-1700X | Dia80x450mm (3.0"x18") | 1700 C |
STATF-1700X | Dia100x450mm (4.0"x18") | 1700 C |
Warranty:Our products are warranted to be free from defects in materials or workmanship for one year from the date of purchase. Within this period, Across International will, at its sole options, replace any components that fail in normal use. Such replacement will be made at no charge to the customer for parts, provided that the customer shall be responsible for any transportation cost. This warranty does not cover consumables and failures due to abuse, misuse, accident or unauthorized alteration or repairs.
Replacement will be shipped to you after photo or other evidence are provided and investigated.
Quality Control Managerment System
STA takes a system approach to manage so that a consistent product is delivered according to customer’s requirement:
STA will review the requirements related to the product. Then ensures the requirements are defined and we have the ability to meet the defined requirements.
During production, we control carefully and keep communication with the clients.
After production we discuss the feedback from productive department and the clients.
Then, we file the customer information including the order requirement so that we improve in the future.
After the ordered has been confirmed, Service Process Diagram is as follows:
To confirm the requirement
To allocate production tasks
To supervise productive process
To deliver the goods and settle accounts
To discuss the feedback from productive department and clients
To file the customer information including order requirement, production process
To make Improvement plan
In order to ensure better quality, we carry out five processes test below:
1. Material inspection and sample test
2. Semi-manufactured goods inspection
3. Process control and inspection
4. Finished products inspection
5. Shipment inspection
Our goal is provide the highest quality products with best service and good delivery time that meet customer requirements; provide continuous improvements in methods and processes and products; work according to an environmentally friendly way of recycling products in all phases of manufacture and use.
Welcome to choose STA vacuum tube furnaces.
Product Description
STATF-1700X high temperature vacuum gas tube furnace is a precision vacuum tubular furnace using quality ceramic STA Super 1800 MoSi2 heating elements as heating elements. It is widely used for materials or chemical lab to sinter all types of new materials samples under vacuum or other gases condition. It is controlled by high precision SCR ( Silicon Controlled Rectifier) digital controller with accuracy +/-1.C and 30 segments programmable up to 1700.C.
Now our vacuum tube furnaces is widely used in university labs for CVD study.
CE Certified 1700C High Temperature Vacuum Tubes Furnace STATF-1800X (Dia 10-120mm) Support Customized size
Model: STATF-1700X | |
Main Specifications: | |
Inside Chamber Size | Dia60x300mm(dia2.5" x 12") (support customized size) |
Standard Working Temperature | <1700 C ( continuous ) |
Maximum Working Temperature | 1700 C ( < 3 hrs) |
Furnace chamber | split type |
Max. vacuum | -0.1MPa |
Temperature Control | 30 steps programmable and PID automatic control |
Heating Rate | 0~ 40.C/ min (suggestion: =< 20.C ) |
Temperature Accuracy | +/- 1 .C |
Furnace structure | Double shell with fan cooling |
Heating Element | STA SUPER 1800 heating elements |
Thermocouple | B type |
Working Voltage | AC 208-240V Single/Three Phase 60/50 Hz (or according to your requirement) |
Max. Power | 8.5 KW |
Net Weight | 180kg |
Detailed Description | |
STATF-1700X tube furnace is a precision bench-top furnace using quality ceramic MoSi2 rods as heating elements. It is widely used for materials or chemical lab to sinter all types of new materials samples under vacuum or other gases condition. It is controlled by high precision SCR ( Silicon Controlled Rectifier) digital controller with accuracy +/-1.C and 30 segments programmable up to 1700.C | |
Standard package included with the furnaces | |
Part description | Quantity |
Tube plug | 4pcs |
quartz tube | 1pc |
vacuum pump | 1pc |
Sealing flange | 1set |
vacuum gauge | 1pc |
Thermal couple | 1 pc |
Stainless steel hook | 1 pc |
Thermal gloves | 1 pair |
Operation manual | 1 pc |
Standard size of STA CVD tube furnace:
Model | Chamber size (OD x heating length) | Max. Temperature |
STATF-1700X | Dia40x300mm (1.5"x12") | 1700 C |
STATF-1700X | Dia40x450mm (1.5"x18") | 1700 C |
STATF-1700X | Dia60x300mm (2.5"x12") | 1700 C |
STATF-1700X | Dia60x450mm (2.5"x18") | 1700 C |
STATF-1700X | Dia80x300mm (3.0"x12") | 1700 C |
STATF-1700X | Dia80x450mm (3.0"x18") | 1700 C |
STATF-1700X | Dia100x450mm (4.0"x18") | 1700 C |
Warranty:Our products are warranted to be free from defects in materials or workmanship for one year from the date of purchase. Within this period, Across International will, at its sole options, replace any components that fail in normal use. Such replacement will be made at no charge to the customer for parts, provided that the customer shall be responsible for any transportation cost. This warranty does not cover consumables and failures due to abuse, misuse, accident or unauthorized alteration or repairs.
Replacement will be shipped to you after photo or other evidence are provided and investigated.
Quality Control Managerment System
STA takes a system approach to manage so that a consistent product is delivered according to customer’s requirement:
STA will review the requirements related to the product. Then ensures the requirements are defined and we have the ability to meet the defined requirements.
During production, we control carefully and keep communication with the clients.
After production we discuss the feedback from productive department and the clients.
Then, we file the customer information including the order requirement so that we improve in the future.
After the ordered has been confirmed, Service Process Diagram is as follows:
To confirm the requirement
To allocate production tasks
To supervise productive process
To deliver the goods and settle accounts
To discuss the feedback from productive department and clients
To file the customer information including order requirement, production process
To make Improvement plan
In order to ensure better quality, we carry out five processes test below:
1. Material inspection and sample test
2. Semi-manufactured goods inspection
3. Process control and inspection
4. Finished products inspection
5. Shipment inspection
Our goal is provide the highest quality products with best service and good delivery time that meet customer requirements; provide continuous improvements in methods and processes and products; work according to an environmentally friendly way of recycling products in all phases of manufacture and use.
Welcome to choose STA vacuum tube furnaces.